Deskripsi Produk | Cold Lab Chamber SYSTEM is optimized for keeping test
material or Incubation test at Low Temperature - General Laboratory Refrigerator
for Low Temperature test
- Special Pair Glass Door without Dew
- Temperature
Controller for High Precision ( 0.1'C Unit Control)
- Security Key Locker and
Waterproof LED Lamp for checking inside chamber
- Thermal Recorder for monitoring
of inside chamber(V320, Option )
- Forced AIR Circulation Type for high Precision
Uniformity
- Urethan Insulation for keeping low temperature
- Adjustable Wire Shelves
- Independent
safety Device for Over Heating and Cooling
- Optional Items : Access Hole, Outlet and others
Test condition can be set easily by PID Controller is focus
on Customer's convenience and expediency, High Precision temperature is available
by 0.1'C unit control. High efficiency keeping test material or test can be
possible by trustworthy safety device.
| | | Digital P.I.D Controller for Customer's convenience | Security Key Lock | Movable Wheel & Supporter |
|
| Trustworthy Safety Device for Temperature | | Wire shelves for safe storage and Tempered Glass Door | Strong Main Body
|
TRVS-1302L(1125Liter)
|
.
The best condition on keeping material or Temperature test on
low temperature.
|
. This unit is the
Refrigerator for keeping material on low temperature.
Also, Tissue culture
room of hospital, Laboratory and Food chemistry room
and others to be
cultured common germs(colon bacterium , Vacteria, etc..).
Beside of keeping
material, this unit is used for storage test, germs
culturing,
environmental change
test and etc.
|
. Precision control is possible by DIGITAL PID CONTROLLER.
|
. Realization of precision temp.distribution are possible
by forced air circulation.
|
. Special Pair Glass
Door without Dew
|
. There are
included trustworthy safety device like over
heating/cooling protector.
|
. Temperature Controller
for High Precision ( 0.1'C Unit Control)
|
1. Uniform Temperature Control |
| Cooling air is circulated in whole chamber from upper to lower by Dual Blower Fan. It makes high uniformity in chamber. Automatic Defrost System can be kept inside Tempearture evenly | 2. Precision Temperature Control | Temperature Sensor is checked about inside Temperature, Precision Temperature Control is possible by PID Controller. | 3. High Trustworthy | Tempered Pair Glass can be checked about Status in Chamber well. If some error for Temperature are occurred on the unit, Causes are checked by Dual safety device for High and low Temperature Limit. User can check and treat the problem immediately. Status report is printed out immediately by thermal recorder, user can check about Temp. change, Power Failure , Door open, and other changes immediately. | 4.Temperature Distribution and Precision |
| [TEMP. Distribution on 4'C in Chamber] [TEMP.Precision on 4'C in Chamber]
|
Service for Medical Refrigerator
1. Wired·Wireless Alarm Service | | | | | | | | - When Emergency condition are occurred, it is not only printed out by Thermal Recorder, but also it is noticed to user by wire or wireless method.. | | - If Temp. error is occurred, safety device for Low and High TEMP. Limit are checked about this problem first. Lamp is on with Alarm and status is printed out by thermal recorder. If error is occurred on the unit, problem status can be called or sent some text messages to user immediately. | | ※ Depends on communication condition on user site, service possibility can be different. Discuss us about service condition enough in advance, please. | | 2. PC Monitoring Service | | | | - PC Monitoring Program was developed by VISION SCIENTIFIC CO.,LTD can be checked and controlled about TEMP. Error in chamber on real time. All data and status are printed out every 1min interval. | | | 3. Calibration Service | | | - Available Calibration service and Test report or Calibration report for the unit. (This Service can be changed depednds on local condition) | | | 4. Optional Accessories |
| | [Thermal Recorder] [Chart Recorder] [7days Chart Recorder] | | |
Cold
Lab Chamber
|
TRVS-1302L
|
Dimension
(in)
|
1,140
x 690 x 1,430(H)mm
|
Dimension
(out)
|
1,257
x 800 x 2,020(H)mm
|
Capacity
|
1125Liter
|
Shelves
|
8EA
|
Door
|
Tempered
Safety Glass
|
2
Door
|
Weight
|
178Kg
|
Power
|
220V,720W,60Hz
|
Temp.
Range
|
0-10℃
|
Temp.
Controller
|
Digital
P.I.D Controller
|
Temp.
Accuracy
|
±2℃ at 5℃
|
Illumination
|
Water
Proof LED Lamp
|
Display
|
Dual
LED Display
|
Recorder
|
Thermal
Recorder(Option)
|
Defrost
Device
|
Automatic
Type
|
Material
(in)
|
Stainless
steel
|
Material
(out)
|
Steel
with Powder coating, Stainless
|
Safety
Device
|
Exclusive
High & Low Temp. Protector
|
Standard Items- Main Body, Key Lock, 8 Shelves(Teflon Coating), Power Cable, Manual
|